Exhaust gas aftertreatment system DCU control unit function tester

Hotline:4008198001
Exhaust gas aftertreatment system DCU control unit function tester
Details

Exhaust gas aftertreatment system DCU control unit function tester

 

1. Equipment pictures

 

   Adopt 6001 standard cabinet form.

 

 

2. Device function description

 

1. Online burning program

2. Measurement of supply voltage and internal voltage module voltage

3. Test of CAN communication

4. Simulation of air flow sensor and detection of DCU acquisition value

5. Simulation of urea tank temperature and liquid level sensor and detection of DCU acquisition value

6. Simulation of catalyst inlet and outlet temperature sensors and detection of DCU acquisition values

7. Simulation of PTO signal and detection of DCU acquisition value

8. DCU control fault light status detection

9. DCU controls the detection of the liquid level lamp status of the urea tank

10. DCU detection of heating water valve state control

11. DCU detection of backup drive status control

 

Technical indicators

 

1. Voltage acquisition (16-bit AD is used for voltage acquisition)

A. Multi-channel: 32 channels

B. Voltage measurement range: DC 0~100V

                 AC 0~100V

C. Measurement accuracy: better than ±(1%+0.01V)

 

2. High-speed digital IO

A. Multi-channel: 32 channels

B. Level output: high is 5V

Low is 0V

C. Level input: greater than 3.5V is logic high

less than 1.5V is logic low

 

3. Load connection switch (provide load switch, external load according to actual needs)

A. Maximum switching voltage: 250V

B. Maximum switching current: 5A

C. Maximum switching power: 150W

D. Switch channel: 16 channels per board (can be expanded as needed)

 

4. Program-controlled voltage (12-bit DA output in common)

A. Number of channels: 8 channels

B. Voltage output range: 0-5V step 1mV

C. Voltage output accuracy: ±(1%+0.01V)

D. Current drive capability: 0-100mA

 

5. Sampling resistor output

A. Number of channels: 5 dual-point outputs

B. Resistance accuracy ±2%

C. Withstand voltage range 0-24V

D. Endured power consumption 0.25W

E. 8 resistance gears with fixed resistance value per channel

 

6. Program-controlled frequency source (8 channels of the same source)

A. Number of channels: 8

B. Voltage: TTL level

C. Driving capacity: less than 50mA

D.9833 Program-controlled frequency source range: 10Hz-2MHz

               Accuracy: ±1%+1Hz

             Resolution: 1Hz

 

7. Current acquisition

A. Current measurement range 0-32A

B. Measurement accuracy ±3%

C. Response time 1ms

 

 

3. Comparative analysis of project import efficiency and manual testing

 

  artificial SRC functional test system  
Detection speed 50S/PIC 15S/PIC  
Inspection record No records or manual records Automatically record into the database for easy query and data backtracking  
Inspection quality May be influenced by human factors Automatically judge according to the settings, without the influence of human factors  
Detection efficiency Working for a long time, people are easily fatigued, resulting in a decrease in efficiency and also affecting the quality 24 hours continuous work  

 

Fourth, equipment import cost recovery cycle accounting

project before import after import
Single detection time (seconds) 50 15
8 hours capacity per station 576 1920